Combi Boiler Cuts Out When Another Tap Is Turned On?

By Emergency Plumb,

Kettle’s on, you’re rinsing a pan under the hot tap, and your partner turns on the bathroom basin to brush their teeth. Your hot water goes lukewarm, then properly cold. They turn their tap off and, a few seconds later, the heat comes back. Annoying, and a bit worrying when the house is already chilly. Most of the time it’s not a dying boiler. It’s a combi that’s being starved of water.

Short answer: A combi boiler only lights while a certain amount of water is flowing through it. Open a second tap and the water coming into your home gets shared out, so the flow through the boiler drops. If it falls below the boiler’s minimum, the burner shuts off until there’s enough flow again. Check your stopcock is fully open, then measure your flow. A weak or part-closed supply, a clogged boiler inlet filter or a tired flow sensor are the usual suspects.

Why does a second tap make my combi switch off?

A combi has no hot water tank. It sits waiting until it senses water moving, then fires up and heats that water on its way through. Viessmann puts it simply: combis heat water straight from the mains and send it to your taps at mains pressure, and when the supply is weak or several outlets are in use, a combi may struggle.

The detail that catches people out is the start and stop point. Worcester Bosch’s technical bulletin on minimum flow rates says its combis need between 2 and 3 litres a minute to start a hot water demand, and typically stop at about 1 litre a minute below that. So if you’re only just above the line with one tap on, opening a second one can tip you under it. The boiler goes quiet, the water runs cold, and it relights only when the flow picks up again.

Illustration: a white combi boiler on a kitchen wall above a sink with the mixer tap running, and a utility room with a second sink through the doorway

Illustration made with AI to show a combi boiler and two taps in the same home. It is not a photo of one of our jobs.

Is it the boiler, or the water coming in?

Work through these in order. None needs tools.

  1. Open the stopcock all the way. Usually under the kitchen sink. Anticlockwise until it stops, then a quarter turn back. A valve left half shut by a previous job is surprisingly common. If it’s stiff, our guide to a seized or stuck stopcock explains how not to snap it.
  2. Time a bucket at the kitchen cold tap. Use a bucket with litre marks and a phone stopwatch. Work out litres per minute.
  3. Run one hot tap on its own. If it stays hot for a few minutes, the boiler can heat water when it gets enough.
  4. Now open a second tap and watch the boiler display. If the flame symbol or hot water light drops out the moment the second tap opens, it’s a flow problem.
  5. Try a different pair of taps. If it only happens with the shower, the mixer valve or a scaled shower head may be choking the flow on that outlet.

If your hot is weak all the time, even with nothing else running, read our guide to hot water pressure being low while the cold is fine. If it’s specifically the washing machine that kills your shower, there’s a separate guide on hot water going cold when the washing machine fills.

What it usually is

What you noticeUsual cause
Boiler cuts out with any second tap, hot or coldIncoming supply too weak, or stopcock part closed
Only cuts out with the basin or shower onThat outlet is pulling a big share of the flow
Hot water weak even with one tapBlocked filter on the boiler’s cold inlet, or scale inside
Boiler starts and stops on a trickleFlow sitting right on the boiler’s minimum
Temperature swings rather than cutting outOutlets fighting over limited flow
All taps weak, all dayA supply or pipe problem, see low water pressure in the house

How do we sort it?

We begin with what’s cheap and quick: every valve on the cold supply, the boiler’s inlet filter, and the flow sensor. Grit and London limescale love that filter. Then we measure the flow at the boiler with one outlet open and with two.

What happens next depends on what we find:

  • Unbalanced outlets. Worcester Bosch notes that flow restrictors on taps share the boiler’s output more evenly, so one outlet doesn’t starve another. A greedy basin mixer can be tamed this way, but we never go below the recommended rates.
  • A narrow or tired supply. An old lead or undersized pipe from the street simply can’t feed a combi and a second tap. Replacing it is often the real fix, and our lead pipe replacement page explains the work.
  • A boiler fault. If the flow is good and it still cuts out, it’s the sensor, the diverter valve or the controls, and we repair it as a central heating repair.

Viessmann adds that you can’t fit a pump to a combi, so if your home simply asks for more hot water at once than the supply can give, it may be time to talk about a different system.

It’s all charged by the hour with no call-out fee: £110 for the first hour, £45 for each half hour after, plus parts. The full breakdown is on our prices page.

No hot water at all tonight?

If it’s gone from cutting out to not lighting at all, and the house is getting cold, our 24-hour emergency plumbers can help. We cover London and the M25 towns, usually reach you in 60 minutes, and you can see everything else we do on our emergency plumber in London page. Call or WhatsApp 07861 933265 and tell us what the boiler display is showing.

Questions people ask

Why does my combi stop heating when someone else runs a tap?

A combi only fires while enough water is moving through it. When a second tap opens, the water coming into the house is split two ways, so less goes through the boiler. If the flow through it drops under the level it needs to stay lit, the burner switches off and you get cold water until the other tap is closed.

How much flow does a combi need to keep going?

It varies by model. Worcester Bosch's technical bulletin on its own combis says a hot water demand starts at between 2 and 3 litres a minute, and the boiler usually stops at about 1 litre a minute below that starting rate. Your boiler's manual gives the figures for your model.

Does it matter if the other tap is hot or cold?

Both can cause it. A cold tap takes water before it ever reaches the boiler. A second hot tap shares the boiler's own output, so each outlet gets less and the temperature at each one can wobble. Either way, the total coming in from the street is the limit.

Can I fit a pump to my combi to stop it?

No. Viessmann points out that you can't add a shower pump to a combi system. If the mains supply is the weak link, the answer is to improve the supply, balance the outlets, or in some homes change to a different kind of hot water system.

What will it cost to have it looked at?